User guide
Canopy System User Guide Configuring an AP for the Destination
pmp-0229 (Mar 2013)
275
Figure 85: Unit Settings tab of AP, example
The Unit Settings tab of the AP contains an option for how the AP should react when it detects a
connected override plug. You may set this option as follows.
Set to Factory Defaults Upon Default Plug Detection
If Enabled is checked, then an override/default plug functions as a default plug. When the module
is rebooted with the plug inserted, it can be accessed at the IP address 169.254.1.1 and no
password, and all parameter values are reset to defaults. A subscriber, technician, or other person
who gains physical access to the module and uses an override/default plug cannot see or learn the
settings that were previously configured in it. When the module is later rebooted with no plug
inserted, the module uses the new values for any parameters that were changed and the default
values for any that were not.
If Disabled is checked, then an override/default plug functions as an override plug. When the
module is rebooted with the plug inserted, it can be accessed at the IP address 169.254.1.1 and no
password, and all previously configured parameter values remain and are displayed. A subscriber,
technician, or other person who gains physical access to the module and uses an override/default
plug can see and learn the settings. When the module is later rebooted with no plug inserted, the
module uses the new values for any parameters that were changed and the previous values for any
that were not.
See Overriding Forgotten IP Addresses or Passwords on AP, SM, or BH on Page 433.
The Unit Settings tab also contains the following buttons.
Save Changes
When you click this button, any changes that you made on all tabs are recorded in flash memory.
However, these changes do not apply until the next reboot of the module.