User guide

Canopy System User Guide Configuring a Point-to-Point Link for Test
pmp-0229 (Mar 2013)
219
The PTP 100 Series BH interface provides a series of web pages to configure and monitor the unit.
These screens are subject to change by subsequent software releases.
You can access the web-based interface through only a computing device that is either directly
connected or connected through a network to the BH. If the computing device is not connected to
a network when you are configuring the module in your test environment, and if the computer has
used a proxy server address and port to configure the module, then you may need to first disable
the proxy setting in the computer.
To toggle the computer to not use the proxy setting, perform Procedure 6 on Page 190.
In the address bar of your browser, enter the IP address of the BHM (default is 169.254.1.1). The
BHM responds by opening the General Status tab of its Home page.
Quick Start Page of the BHM
To proceed with the test setup, click the Quick Start button on the left side of the General Status
tab. The BHM responds by opening the Quick Start tab of the Quick Start page. An example of
this tab is displayed in Figure 71.
Figure 71: Quick Start tab of BHM, example
Quick Start is a wizard that helps you to perform a basic configuration that places a BHM into
service. Only the following variables must be configured:
Region Code
RF Carrier Frequency