Specifications
Four Slot Battery Charger SAC7X00-4000R Troubleshooting
Table 15: Troubleshooting the Four Slot Battery Charger
Problem Cause Solution
Spare Battery Charging
LED does not light when
spare battery is inserted.
Spare battery is
not correctly seat-
ed.
Remove and re-insert the spare battery into the charging slot, ensuring
it is correctly seated.
Spare Battery not charg-
ing.
Charger is not re-
ceiving power.
Ensure the power cable is connected securely to both the charger and
to AC power.
Spare battery is
not correctly seat-
ed.
Remove and re-insert the battery into the battery adapter, ensuring it
is correctly seated.
Battery adapter is
not seated proper-
ly.
Remove and re-insert the battery adapter into the charger, ensuring it
is correctly seated.
Battery was re-
moved from the
charger or charg-
er was unplugged
from AC power
too soon.
Ensure charger is receiving power. Ensure the spare battery is seated
correctly. If a battery is fully depleted, it can take up to five hours to
fully recharge a Standard Battery and it can take up to eight hours to
fully recharge an Extended Life Battery.
Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty
battery.
Cables
Table 16: Troubleshooting the Cables
Symptom Possible Cause Action
MC32N0 amber Charge
LED Indicator does not
light when MC32N0 is
attached.
Cable is not receiving pow-
er.
Ensure the power cable is connected securely to both the
cable and to AC power.
MC32N0 is not seated cor-
rectly in the cable cup.
Remove and re-insert the MC32N0 into the MC32N0 cable
cup, ensuring it is correctly seated.
MC32N0 battery is not
charging.
MC32N0 was detached
from cable or cable was un-
plugged from AC power too
soon.
Ensure the cable is receiving power. Ensure MC32N0 is
seated correctly. If the MC32N0 battery is fully depleted, it
can take up to five hours to fully recharge a Standard Bat-
tery and it can take up to eight hours to fully recharge an
Extended Life Battery.
Battery is faulty. Verify that other batteries charge properly. If so, replace
the faulty battery.
The MC32N0 is not fully
seated in the cable.
Remove and re-insert the MC32N0 into the cable cup, en-
suring it is correctly seated.
During data communica-
tion, no data transmits,
or transmitted data was
incomplete.
Cable was disconnected
from MC32N0 during com-
munications.
Re-attach the cable and retransmit.
Incorrect cable configura-
tion.
See the system administrator.
Table continued…
166 | Maintenance and Troubleshooting
Send Feedback | June 2014 | MN000887A01