2. From the mounting hardware, insert the four M6 screws into the
repeater chassis side fins and partially tighten. See Figure 2.
3. Place the repeater chassis into the bracket by sliding the M6
screws into the receiving slots on the bracket. Torque to 60 in-lbs.
See Figure 3.
Mounting the SLR 1000 Repeater to a Pole
When mounting the SLR 1000 Repeater to a pole, obtain the
PMLN7213_ Pole Mount Kit, and the wall mounting bracket and four
M6 screws included with the repeater mounting hardware An
additional four M4 screws are used for a power supply.
There are two possible options for the pole mount installation:
Using a U-bolt with two ½ in. washers and four ½ in. nuts for poles
with a diameter between 2-2.75 in.
Using two band clamps for poles of any diameter. The band
clamps are not included in the pole mount kit.
Procedure:
1. If using the U-bolt for installation, perform the following actions:
a. Thread two of the ½ in. nuts onto the U-bolt.
b. Place the U-bolt onto the pole and slide the pole mount bracket
onto the U-bolt.
c. Slide the wall mount bracket onto the U-bolt, with the receiving
slots facing upwards, and place the two ½ in. washers, then
the two ½ in. nuts onto the U-bolt, one on each thread. Torque
the outer nuts to 150 in/lb. See Figures 4 and 5.
Figure 2: Location of M6 Screw Mounts
Figure 3. Bracket Receiving Slots
Applicant: Motorola Solutions
Equipment Type: ABZ99FT3096B / 109AB-99FT3096B
Exhibit D2 8 of 14