4-4 Electrical Connections RF Antenna Connections
4.2.2 Antenna Selection
The selection of the antenna is critical to system performance. The selected antenna must be
50 Ohm impedance and capable of at least 50 Watts. Gain antennas may be used to increase
system coverage. Please take note of licensing restrictions when selecting gain antennas. Some
services or regions may have antenna gain or system ERP limitations.
The antenna must be connected to the duplexer with a high grade 50 Ohm transmission line
(hardline). The line must have connectors to match the connectors on the duplexer and antenna.
For proper antenna installation, please also consult the Motorola Quality Standards Fixed Network
Equipment Installation Manual R56 (6881089E50).
It is important that all antenna cables are grounded at the point they enter the
building.
The antenna design is the customer's responsibility. All aspects of the antenna
design must comply with the relevant local regulations.
!
C a u t i o n
!
C a u t i o n