User's Manual

2 Using band clamps for poles of any diameter. The band clamps are not included in the pole mount
kit.
Procedure:
1 If using the U-bolt for installation, perform the following actions:
a Place the two inner ½ in. nuts onto the U-bolt, one on each thread. Adjust each nut
approximately 2 in. on each thread allowing enough clearance between the bracket and the
repeater.
b Attach the pole mount bracket to the U-bolt.
c Slide the wall mount bracket onto the U-bolt, with the receiving slots facing upwards, and
place the two outer ½ in. nuts onto the U-bolt, one on each thread. Torque all four nuts to
300 in/lb. See Figure 34: U-Bolt Bracket Assembly
on page 84.
Figure 34: U-Bolt Bracket Assembly
2 If using the band clamps for installation, perform the following actions:
a Slide the band clamps through the slots on the pole mount bracket and attach the bracket to
the pole.
b Attach the wall mount bracket to the pole mount bracket, with the receiving slots facing
upwards, using two ½ in. bolts and two ½ in. nuts. Torque to 300 in/lb.
3 Insert the four M6 screws, supplied in the repeater package, into the repeater chassis side fins
and partially tighten. See Figure 35: Location of Repeater M6 Screw Mounts on page 84.
Figure 35: Location of Repeater M6 Screw Mounts
4 Place the repeater chassis into the bracket by sliding the M6 screws into the receiving slots on
the bracket. Torque to 60 in-lb. See Figure 36: Bracket Receiving Slots on page 84.
Figure 36: Bracket Receiving Slots
10.3
Electrical Connections
After the repeater equipment has been mechanically installed, electrical connections must be made.
This involves making the following connections to:
power supply,
antenna coax cables
system cables, and
grounding
Figure 37: SLR 1000 Repeater Bottom Panel Connector Names and Locations on page 84 shows
the position of the repeaters external connectors on the bottom panel of the repeater. Table 27: SLR
1000 Repeater Connector Types and Primary Functions on page 84 identifies the connector types as
well as a given connector’s primary function.
Figure 37: SLR 1000 Repeater Bottom Panel Connector Names and Locations
Table 27: SLR 1000 Repeater Connector Types and Primary Functions
Location Connector Type Function(s)
1 M6 TORX Screw Bonding Ground Connection
Table continued…
MN003557A01-AA
Chapter 10: SLR 1000 Installation
84 Send Feedback
Preliminary FCC Filing