LED Definition
Ethernet Link/ Network Connectivity
Reference
Table 10: SLR 1000 Front Panel LED Definitions
LED Function
Name
LED Col-
or
LED State Status Indication
Power/Status Off Off Off
Green Solid Operating Normally, with DC power
Red Flashing Repeater is Disabled (by customer)
Solid Not Operational – Major Alarm
Amber Flashing* Check Alarm Log – Alarm occurred and cleared
but remains latched (configurable)
Solid Repeater Operational – Minor Alarm
Ethernet/ Network
Connectivity
Off Off No Ethernet connection
Green Solid Connectivity/ Linked
Flashing Attempting to connect to the system
Reference Off Off For future use
NOTICE: All LEDs flashing in unison indicate the repeater is booting up.
The RDAC application will be needed when the Status LED is red (solid or flashing). This status
indicates a minor or major alarm. The RDAC application is used to identify the specific alarm
and probable diagnosis to aid in identifying the FRU at fault.
(*) Not supported in initial release.