7.2.7
Ethernet 2
Not supported at this time. Fully compliant with IEEE and 802.3 and 802.3u standards. Supports
10Base-T, 100Base-Tx rates, full duplex, half duplex mode and flow control. See Figure 31: Ethernet 2
Connector on page 75 and Table 31: Ethernet 2 Connector on page 75 for the location of the pins
and the functional characteristics of the connector's pins.
Figure 31: Ethernet 2 Connector
1
8
Table 31: Ethernet 2 Connector
Location Pin Assignment Type Signal Characteristics
1 Ethernet Tx+
Ethernet
Physical Layer
5 V differential data2 Ethernet Tx-
3 Ethernet Rx+
4 Unused N/A
5 Unused N/A
6 Ethernet Rx- 5 V differential data
7 Unused N/A
8 Unused N/A
7.2.8
Auxiliary (Aux)
This connection supports the analog interface to the SLR 5000 series repeater, which includes audio,
station control, station indicators, accessory power, and provisions for timing used in various system
implementations. See the following figure and table for location of the pins and the functional
characteristics of the connector's pins.
MN001436A01-AD
Chapter 7: SLR 5000 Series Back Panel
Send Feedback 75