MOTOTRBO SLR 5000 Series
Repeater
Supplemental Safety and Installation
Requirements
IMPORTANT:
The MOTOTRBO SLR 5000 Series Repeater must be installed in a suitable, in-building
enclosure. A restricted access location is required when installing this equipment into the
end system.
The repeater contains a Class 1 built-in power supply component. It is equipped with an
appliance inlet for connecting to an AC input, as well as DC input terminals which meet
SELV DC circuit requirements.
When installing the equipment, all requirements of relevant standards and local electrical
codes must be fulfilled.
The maximum operating ambient temperature of this equipment is 60 °C. The maximum
operating altitude is 2000 meters above sea level.
The 13.6 VDC output from the power supply to the PA is at an energy hazard level (exceeds
240 VA). When installing into the end system, care must be taken so as not to touch the
output wires.
When the SLR 5000 Series Repeater is used in a DC reverting system, the DC power
supply must be located in the same building as the MOTOTRBO SLR 5000 Series Repeater,
and it must meet the requirements of a SELV circuit.
MN001436A01-AD
MOTOTRBO SLR 5000 Series Repeater
Supplemental Safety and Installation Requirements