User's Manual

Table Of Contents
+ AC Input Only
+ DC Input Only
+ AC with Battery Revert
In addition to providing power to the noted FRU and controllers, the PS also provides the following:
AC Failure detect signaling to the Modem
Output over-current protection
Integrated 2 stage 3 amp battery charger
Further details can be found in the individual sections of the respective FRU chapters of this manual.
1.7
Basic Repeater Level Troubleshooting – RDAC and LEDs
Diagnostic tests are available for the Modem, PA, and Power Supply Modules. If a problem occurs
during station operation, it is logged as an alarm that is read with the Repeater Diagnostic and Control
application (RDAC).
Figure 5: RDAC Diagnostic Screen
The station operator will then evaluate the problem locally or remotely, as the station maintains an
Alarm Log with the name of the alarm that has failed since the last power up. Via the RDAC
application's Alarm Log, the alarm messages will aid in identifying the FRU that failed along with the
fault condition.
After booting up the repeater, the seven LEDs (Power/Status, Tx Slot 1, Tx Slot 2, Rx Slot 1, Rx Slot 2,
Network, and Reference LEDs) will flash in unison.
The general status and condition of the SLR 5000 series repeater can be obtained by observing the
seven LED indicators on the front panel. Table 8: Front Panel LED indicators on page 45 shows the
LED symbols and their meaning, while Table 9: SLR 5000 Series Front Panel LED Definitions on page
46 identifies the information conveyed via the LED indicators.
Table 8: Front Panel LED indicators
LED Definition
Status
Tx A Tx Slot 1
Rx A Rx Slot 1
Table continued…
MN001436A01-AD
Chapter 1: SLR 5000 Series Repeater
Send Feedback 45