User's Manual
Table Of Contents
- SLR 5000 Series Installation
- 12.1 Pre-Installation Considerations
- 12.2 Mechanical Installation
- 12.3 Electrical Connections
- 12.4 Post Installation Checklist
- 12.5 Installing Repeater Hardware Options
- Appendix A: Accessories
- Appendix B: Replacement Parts Ordering
- Appendix C: Motorola Solutions Service Centers
- Appendix D: SLR 5000 Series Third-Party Controllers
- Appendix F: MOTOTRBO Repeater – EME ASSESSMENT
- Glossary of Terms and Acronyms
- Alert tone
- Analog
- ASIC
- AUX
- Band
- CTCSS
- Clear
- Conventional
- CPS
- Default
- Digital
- DPL
- DSP
- EIA
- ESD
- EU
- FCC
- FM
- Frequency
- FRU
- FSK
- GNSS
- GPIO
- IC
- IF
- I/O
- kHz
- LCD
- LED
- MDC
- MHz
- MISO
- MOSI
- PA
- PC Board
- PFC
- PL
- Programming Cable
- PTT
- Receiver
- Repeater
- RF
- RSSI
- Rx
- SCM
- SELV
- Signal
- SINAD
- SLR
- Spectrum
- SPI
- Squelch
- TOT
- TPL
- Transceiver
- Transmitter
- Trunking
- Tx
- UHF
- USB
- VCO
- VCTCXO
- VHF
- VIP
- VSWR
- WLAN
Procedure:
1 Install the two power screws from the Power Supply Module into the PA board to 6.5 in-lb
(0.7 N-m) using a T10 Torx driver.
2 Install the two power screws from the Power Supply Module into the Modem board to
6.5 in-lb (0.7 N-m) using a T10 Torx driver.
CAUTION: Ensure that correct polarity of the modem power supply module is observed
otherwise damage may occur.
Figure 73: Installing Power Screws
3 Secure the "C3" cable from the Power Supply Module to the chassis in the pocket near the
Power Supply Module using a cable clamp (PN: 42009306001) and a M4 x 0.7 x 10 mm screw
(PN: 0310909A61) torque to 15 in-lb (1.7 N-m) using a T20 Torx driver.
Figure 74: Securing Cables
4 Secure the "C2", "C4" and "C6" cables from the Power Supply Module to the chassis near the
Modem using a cable clamp (PN: 42009306002) and a M4 x 0.7 x 10 mm screw
(PN: 0310909A61) torque to 15 in-lb (1.7 N-m) using a T20 Torx driver.
5 Secure the "C6" cable from the Power Supply Module to the chassis near the PA Module using
a cable clamp (PN: 42009306001) and a M4 x 0.7 x 10 mm screw
(PN: 0310909A61) torque to 15 in-lb (1.7 N-m) using a T20 Torx driver.
6 Secure the connector of the "C5" cable between the Power Supply Module and the Modem to
the corresponding Modem Connector.
7 Assemble the coaxial cable (PN: 30012084001) to the connectors on the Modem and PA
Module
NOTICE: When installing the flexible cables, directly insert the cable parallel to the
connector to avoid damage to the connector. Do not assemble at angle.
8 Assemble the flex cable (PN: 30012085001) between the PA Module and the Modem. Install the
PA Module side first.
9 Assemble the flex cable (PN: 84007002001) between the Modem and the Front Panel.
MN001436A01-AD
Chapter 11: SLR 5000 Series Maintenance and Disassembly/Reassembly
Send Feedback 113