User's Manual

Table Of Contents
Table 43: Callout Legend
Label Description
1 USB Service Port
12.3.1
Power Supply Connections
12.3.1.1
AC Input Power Connection
CAUTION:
Do not apply AC power to the repeater at this time. Make sure that the circuit breaker
associated with the AC outlet is turned OFF.
The AC socket-outlet must be installed near the equipment and must be easily accessible.
Each repeater is shipped with an 2.5 m (8 ft) 3-conductor line cord. See Figure 81: Back Panel
Connector Names and Locations on page 129 for AC power inlet connector. Insert the plug into an
appropriate grounded outlet.
12.3.1.2
DC Input Power Connection/ DC Charger Connection
For DC operation, the DC source power is connected to the repeater through the DC power inlet
connector shown in Figure 81: Back Panel Connector Names and Locations on page 129. The
operation is also described in the “Battery Connection” section of this chapter. The DC source must be
located in the same building as the repeater, and it must meet the requirements of an SELV circuit.
CAUTION: Ensure that the appropriate voltage is connected with a nominal 13.6 VDC (11 –
14.4 VDC).
12.3.1.3
Ground Connection
The repeater is equipped with a ground screw located on the back panel. Figure 81: Back Panel
Connector Names and Locations on page 129 shows the location of the grounding screw. Connect the
ground screw to the site ground point. The size of the wire used for this connection must be 8 AWG
minimum.
CAUTION:
Refer to Motorola Solutions Quality Standards Fixed Network Equipment Installation Manual
R56 (which can be obtained by ordering CDROM 9880384V83), for complete information
regarding lightning protection.
The repeater should only be connected to a battery supply that is in accordance with the
applicable electrical codes for the end use country; for example, the National Electrical Code
ANSI/NFPA No. 70 in the U.S.
12.3.1.4
Battery Connection
Battery backup interface offers the capability of connecting to battery backup power in the event of an
AC power line failure. The battery backup system is connected to the repeater through the DC inlet
connector on the rear panel of the repeater. See Figure 81: Back Panel Connector Names and
Locations on page 129 for the location of the DC inlet connector.
MN001436A01-AD
Chapter 12: SLR 5000 Series Installation