User's Manual

Table Of Contents
CAUTION: The repeater should only be connected to a battery supply that is in accordance
with the applicable electrical codes for the end use country; for example, the National Electrical
Code ANSI/NFPA No. 70 in the U.S.
12.1.4.5
RF Antenna Connections
The transmit and receive antenna RF connections are made using two separate connectors. Coax
cables from the receive and transmit antennas must be connected to their respective connectors. The
position of these connectors is shown in Figure 81: Back Panel Connector Names and Locations on
page 129, and their respective connector types are noted in Table 42: Connector Type and Primary
Function on page 129.
12.1.4.6
System Cable Connections
System connections are made through the Aux and/or Ethernet connectors located on the back panel
of the repeater. The positions of the Aux and Ethernet connectors are shown in Figure 81: Back Panel
Connector Names and Locations on page 129.
See Auxiliary (Aux) on page 75 for a description of the signaling that is supported by the Aux
connector.
12.1.5
Equipment Mounting Methods
The SLR 5000 Series Repeater may be mounted in a rack or cabinet. The repeater may also be
configured as a desk or wall mount unit.
The repeater can be mounted:
In a floor-mount cabinet. Each floor-mount cabinet has front and rear vented doors and has the
capacity to hold a minimum of a single repeater (see thermal limitations described under Equipment
Ventilation), and required ancillary equipment. The larger cabinets provide additional room for
supplementary peripheral equipment.
In a rack. Open frame racks accept multiple repeaters and ancillary equipment; EIA 48.3 cm (19
inch) rack configuration.
12.1.5.1
Floor-Mounted Cabinet
The front, side and top views for all available floor-mount cabinets are shown in Figure 78: Floor Mount
Cabinet on page 123. See Table 39: Cabinet Models on page 122 for the cabinet models and
associated description.
Table 39: Cabinet Models
Model Description
THN6700 12 in. (30.48 cm) indoor cabinet
THN6701 30 in. (76.2 cm) indoor cabinet
THN6702 46 in. (116.84 cm) indoor cabinet
Refer to Equipment Ventilation on page 120 for recommended ventilation clearances. For improved
access to the unit, tray slides are available as shown in Table 40: Cabinet Slide on page 123.
MN001436A01-AD
Chapter 12: SLR 5000 Series Installation
122 Send Feedback