Installation Manual
Table Of Contents
- Foreword
- General Safety and Installation Standards and Guidelines
- Declaration of Conformity
- MOTOTRBO SLR 1000 Repeater Supplemental Safety and Installation Requirements
- Environmental Information
- Document History
- Contents
- List of Figures
- List of Tables
- List of Procedures
- Related Publications
- Summary of Bands Available
- Commercial Warranty
- SLR 1000 Repeater
- SLR 1000 Satellite Receiver
- SLR 1000 Transceiver Board
- SLR 1000 Front Panel
- SLR 1000 Bottom Panel
- SLR 1000 Test Equipment And Service Aids
- SLR 1000 Performance Check or Testing
- SLR 1000 Programming and Tuning
- SLR 1000 Maintenance and Disassembly/Reassembly
- SLR 1000 Installation
- 10.1 Pre-Installation Considerations
- 10.2 SLR 1000 Repeater Package Contents
- 10.3 Mounting the SLR 1000 Repeater to a Wall or Ceiling
- 10.4 Mounting the SLR 1000 Repeater to a Pole
- 10.5 Electrical Connections
- 10.6 General Bonding and Grounding Requirements
- 10.7 General Cabling Requirements
- 10.8 Post Installation Checklist
- Appendix A: Accessories
- Appendix B: Replacement Parts Ordering
- Appendix C: Motorola Solutions Service Centers
- Appendix D: SLR 1000 Series Third-Party Controllers
- Appendix E: MOTOTRBO Repeater EME Assessment
- Glossary of Terms and Acronyms
- Alert tone
- Analog
- ASIC
- AUX
- Band
- CTCSS
- Clear
- Conventional
- CPS
- Default
- Digital
- DPL
- DSP
- EIA
- ESD
- EU
- FCC
- FM
- Frequency
- FRU
- FSK
- GNSS
- GPIO
- IC
- IF
- I/O
- kHz
- LCD
- LED
- MDC
- MHz
- MISO
- MOSI
- PA
- PC Board
- PFC
- PL
- Programming Cable
- PTT
- Radio Management
- Receiver
- Repeater
- RF
- RSSI
- Rx
- SCM
- SELV
- Signal
- SINAD
- SLR
- Spectrum
- SPI
- Squelch
- TOT
- TPL
- Transceiver
- Transmitter
- Trunking
- Tx
- UHF
- USB
- VCO
- VCTCXO
- VHF
- VIP
- VSWR
- WLAN
Frequency
Band
Bandwidth Power Level
UHF 400–512 MHz 1–10 W
Self-Quieting Frequencies
When using an indoor antenna, there is a potential for degraded receiver performance with the
following frequencies:
VHF UHF
147.03125 MHz 400 MHz
150 MHz 403.2 MHz
153.6 MHz 422.4 MHz
425 MHz
441.6 MHz
450 MHz
460.8 MHz
475 MHz
480 MHz
499.2MHz
500 MHz
518.4 MHz
525 MHz
Return to Process
SLR 1000 Repeater on page
28
1.4
Repeater Specifications
The SLR 1000 Repeater meets the following Radio Frequency (RF) operating specifications.
Table 7: SLR 1000 Repeater General Specifications (All Bands)
Parameter Specifications
Number of Channels 64
Frequency Generation Synthesized
Input Voltage DC 10.8–15.6 VDC
Station Weight 10 lbs (4.56 kg)
Temperature Range -30 °C to +60 °C (-22 °F to +140 °F)
Ingress IP65, NEMA 4
Antenna Connectors Tx: N-type Rx: N-type
Modes of Operation Half-Duplex/ Duplex
MN003557A01-AF
Chapter 1: SLR 1000 Repeater
37