Installation Manual

Table Of Contents
evaluated against the ICNIRP reference levels and FCC MPE limits alongside the corresponding peak
equivalent plane wave power density values.
Table 35: Compliance Distance in General Public Exposure (VHF)
Antenna Kit or Model
Number
Evaluation Fre-
quency (MHz)
Compliance Dis-
tance (m)
Equivalent plane
wave power density
(W/m
2
)
HKAD4003 136-154 0.52 1.94
HKAD4004 146-164 0.55 1.95
HKAD4005 160-174 0.59 1.99
Table 36: Compliance Distance in Occupational-Type Exposure (VHF) on page 142shows the
compliance distance for each evaluated VHF antenna applicable to occupational-type exposure
conditions and evaluated against the ICNIRP reference levels and FCC MPE limits alongside the
corresponding peak equivalent plane wave power density values.
Table 36: Compliance Distance in Occupational-Type Exposure (VHF)
Antenna Kit or Model
Number
Evaluation Fre-
quency (MHz)
Compliance Dis-
tance (m)
Equivalent plane
wave power density
(W/m
2
)
HKAD4003 136-154 0.23 9.9
HKAD4004 146-164 0.25 9.4
HKAD4005 160-174 0.27 9.5
Return to Process
MOTOTRBO Repeater EME Assessment on page 133
E.6
Compliance Boundary Description
The compliance boundary is defined as all surfaces of a cylinder surrounding the antenna with the
minimum separation distance from the antenna established by the compliance distance from the
proceeding tables in EME Exposure Evaluation
on page 140. If there is an antenna attached to the
repeater (indoor installation), the repeater enclosure is considered as part of the antenna.
For EME Exposure Evaluation in UHF band performed with respect to the U.S. FCC Regulation, this
compliance distance for indoor installation is 46 cm for General Public exposure conditions and 20 cm
for occupational-type exposure conditions. For the outdoor installations, the compliance distance is 20
cm for both general public and occupational-type exposure conditions.
For EME Exposure Evaluation in UHF band performed with respect to the ICNIRP guidelines, the
compliance distance is 20 cm for indoor and outdoor installations and is applicable to both general
public and occupational-type exposure conditions.
It should be noted that based on the foregoing analysis, the 20 cm distance is conservative for
occupational exposure and may be reduced significantly by carrying out SAR measurements.
For the EME Exposure Evaluation in VHF performed with respect to both the ICNIRP guidelines and
U.S. FCC Regulation, this compliance distance is 59 cm for General Public exposure conditions and 27
cm for occupational-type exposure conditions.
MN003557A01-AF
Appendix
E: MOTOTRBO Repeater EME Assessment
142