Assembly Instructions

No. Description
1 Black Stick
4 Cover the lightbar gasket retainers hole with seal, gasket, and ground cable gland, if no wire is
inserted.
5 The lightbar gasket should be replaced at each reassembly of the wire.
NOTICE: Use of other cable gauges except as recommended in this manual may result
in water intrusion. Any reassembly of wire needs a new lightbar gasket replaced. If the
current loading for one wire is higher than 12 A, the wires should be split before being
assembled to the URC system. Wires kit (PMKN4109_) is provided to ease installation of
the URC. Incorrect use of the wires kit, for example, improper connection at external
loose end wires, may impact the robustness of the URC.
6 Remove the wires and gasket residual inside the URC after the wire installation, before closing
the top housing of the URC.
3.2.4
Installing the O7/O9 to URC Cable
The O7/O9 to URC cable (Motorola Solutions part number 3064153H02) can be assembled either
before or after reassembling the top housing.
Procedure:
1 Insert the RJ45 port of the cable into the RJ45 connector on the URC and turn the locking collar
90° to the right to ensure that it is locked properly.
2 Test if the cable is locked properly by trying to pull out the cable.
Figure 86: O7/O9 to URC Cable Installation
MN005720A01-AB
Chapter 3: Universal Relay Controller Installation
83