User's Manual

Table Of Contents
63
MN003563A01-B
Troubleshooting and Maintenance
Send Feedback
Perform this procedure to hard reset the LXN 500.
Procedure:
1. Press and hold the Power button for more than 15 seconds.
Result: all LEDs on the front panel turn off.
2. Press and hold the Power button for four seconds and release when all LEDs begin to flash
green. Wait until the LEDs are steady green.
Resetting the eNodeB
Use the Reset the eNodeB option when performing configuration and the LXN 500 fails to operate (one
or more RADIO LED illuminate orange or red).
Perform this procedure to reset the LXN 500.
Procedure:
1. Sign in to the LXN 500 O&M Configuration site (See Signing In on page 20).
Click on and select Reset the eNodeB.
Result: The eNode re-boots and RADIO LED illuminates green.