User's Manual
Table Of Contents
- Copyrights
- Contact Us
- Document History
- FCC Information
- About LXN 500
- Overview
- Operation and Configuration
- Getting Started
- Powering On
- Powering Off
- What is Required for Configuration
- Connecting the LXN 500 to a Laptop
- Signing In
- Viewing System Notifications
- Signing Out
- Account Management
- Adding a Single Subscriber (UEs)
- Deactivating/Activating Subscriber
- Importing Subscribers From .csv File
- Deleting Subscriber
- Deleting All Subscribers
- UE Activity
- Statistics
- Setting the eNodeB
- Setting the System
- About LXN 500
- Configuring the DragonForce Server
- Configuring the WAVE 5000 Server
- Provisioning the Mobile Device (UE)
- Vehicle Installation
- Troubleshooting and Maintenance
- Technical Specifications
MN003563A01-B
Operation and Configuration
34
Send Feedback
Iperf has client and server functionality, and creates data streams to measure the throughput between
the two ends - the mobile device functions as a server and the LXN 500 as client.
Figure 2-14
Communication Diagnostics
Built in Test
The Built in Test is a preset network performance test performed between the LXN 500 and the mobile
device. The test diagnose the UDP capacity between the LXN 500 and the mobile device at 5mbps.
Perform this procedure to test the LXN 500 communication.
Procedure:
1. Click Communication to test the LXN 500 communication.
Result: The Communication test screen is displayed.
2. Check Built in Test.
3. Check Short for a quick 10 seconds communication test or Continuous (Hours) and enter the
req
uired duration of the test.
4. In the IP Address field, enter the IP address of the mobile device used for the test.
NOTE Most Android devices display the IP address of the device under: Settings → About → Status →
IP Address.
5. Enter the number of communication port used for the test (Default port number is 5001).
NOTE If you do not know the port number, leave this field empty.