Iperf has client and server functionality, and creates data streams to measure the throughput between
the two ends - the mobile device functions as a server and the LXN 500 as client.
Figure 2-14
Communication Diagnostics
Built in Test
The Built in Test is a preset network performance test performed between the LXN 500 and the mobile
device. The test diagnose the UDP capacity between the LXN 500 and the mobile device at 5mbps.
Perform this procedure to test the LXN 500 communication.
Procedure:
1. Click Communication to test the LXN 500 communication.
Result: The Communication test screen is displayed.
2. Check Built in Test.
3. Check Short for a quick 10 seconds communication test or Continuous (Hours) and enter the
req
uired duration of the test.
4. In the IP Address field, enter the IP address of the mobile device used for the test.
NOTE Most Android devices display the IP address of the device under: Settings About Status
IP Address.
5. Enter the number of communication port used for the test (Default port number is 5001).
NOTE If you do not know the port number, leave this field empty.