User's Manual
Table Of Contents
- Application and Integration
- Developers Guide
- DECLARATION OF CONFORMITY
- DECLARATION OF CONFORMITY2Revision History5Purpose Of This Document5Distribution5Related Documentation5Module Descriptions and Specifications6iO15 Modem Product Specificationss6Electrical specifications:6Environmental Specifications6Other Specifications
- Purpose Of This Document
- Distribution
- Related Documentation
- Module Descriptions and Specifications
- iO1500R Evaluation board
- Safety Notice - ATTENTION
- iO1500R Hardware Interfacing Information
- Design Considerations For iO1500R OEM Developers
- Module Software And Interface Modes
- Managing User Image Profiles
- How To Use Hayes Compatible Packet Data mode
- iDEN data modules – Software integration.
- Additional Information For Registering and Going Offline
- Summary Of AT Commands
- Appendix A: Requirements For FCC Testing
How to use Hayes Compatible Packet Data mode (Continued)
This command will then instruct the DCE (iO1500R module) to originate a call:
ATd <IP_address>..<port#>
Where <IP_Address> = n.n.n.n OR n,n,n,n where 1<n<255, and
<port#> is optional ..p or ,,p 1<=p<= 65535
<IP_address> and <port#> MUST be separated by two dots”..” or two commas
“,,”, but no matter which character is used, there must be 2 of them.
Example: ATd 128.54.88.104..80
will tell the iO1500R to connect to the IP address shown above, and through port #80.
The DCE will respond with: ”Connect <baud rate>”, which means the module is
connected at the baud rate displayed.
1. Continue to work. Transmit and receive data from the other side.
2. To disconnect the call and get back to command mode type +++.
3. The module will respond with “OK”. Then type ATH to hang up.
Other Useful AT Commands
View stored parameters with the AT&V command
To verify that the right image is used enter this command: AT&V
The iO1500R will display several lines of information regarding the current setup of
the module. The very first line of information will display “Active User Image”. If
the iO1500R is in packet data mode, the display will read “Active User Image: 2”.
The AT&V query command also displays the current status of the AT+ws45 and
AT+ws46, a sanity check to determine if the module is setup in Hayes Compatible
Packet Data mode, or any other mode.
How to configure the baud rate with the AT+IPR command
Configure the iDEN data module for the baud rate of your DTE. The default baud rate
of the module is auto baud. Do not leave as auto baud. To configure the baud rate of
the iDEN data module, use this command:
AT+IPR=baud rate
Example: AT+IPR=19200 will set the baud rate to 19200.
The status of the current baud rate setting can then be shown with the baud rate query:
AT+IPR?
The iO1500R will respond back with: +IPR: 19200