User's Manual

9-28 68P81093C75-A
For ASTRO stations only:
Simulcast/ASTRO Launch Time Offset
For 6809 Trunking stations only:
TDATA
Wireline
Physical Replacement of
the Wireline Module
1. Turn off the station’s power by unplugging the AC and DC
power cords from the top panel.
2. Remove the eight Phillips screws from the edges of the station’s
top panel and lift the chassis out of the case.
3. Remove the cover plate on the left end of the front of the station
by removing the two screws from the front of the plate, then
removing the four Phillips screws from the side and bottom
edges of the plate.
4. Pull out the old Wireline Module by gripping its front, right
corner (where there are no parts on the board).
5. Set all jumpers on the replacement board to match those on the
faulty board. These include the following:
Input/ouput impedance matching jumpers
Two-wire/four-wire select jumper
DC remote control selection jumpers
6. Insert the new module. Make sure it is in the cardguides; push it
firmly into the chassis until it seats into the card-edge
connectors on the backplane. (Do not slam the board against the
backplane or push any harder than necessary to seat the
connectors.)
7. If desired, power up the station while it is still out of the case to
make sure the module is securely in place. The LEDs on the
Wireline should blink rapidly, indicating that firmware is
transferring from the SCM to the Wireline Module. When the
blinking stops, the transfer is complete.
If any of the LEDs do not light or are dim, one or more of the
modules are not seated properly. Unplug the station before
continuing to the next step.
8. Reassemble the station by reversing Steps 2 and 3.
After Installing the New
Wireline Module
Perform the following alignment procedures as described in the RSS
User’s Guide (part number 68P81085E35):
Rx Wireline
Tx Wireline