User's Manual

68P81093C75-A 9-19
Step 11. Measure the 12dB SINAD sensitivity and make a note
of the level. This level will serve as a baseline for the
receiver sensitivity. If 12 dB SINAD cannot be
achieved, suspect the following:
Test configuration used does not match that shown
in Figure 6B.
Excessive loss in the coaxial cables or coupler.
Step 12. Remove the cable connecting the coupler to the top
panel receive port. Connect the coupler to the
duplexer’s antenna port. Connect the duplexer’s
receive port to the station’s top panel receive port, as
in normal station operation. (See Figure 6B.)
Step 13. Measure the 12 dB SINAD once again, and note the
result. The difference between this 12 dB SINAD level
and the level measured in Step 11 reflects the insertion
loss of the duplexer. The difference should be no
greater than approximately
VHF: 1.3 dB
UHF: 1.6 dB
800 MHz: 1.5 dB
If the difference is greater, suspect the following:
Duplexer receive and transmit ports are reversed
Loose or damaged cables between the duplexer and
the station
Figure 9. Disabling the Transmitter
Press and hold
Shift Button.
Station Control
Module
Exciter
Module
MAEPF-27037-O
1
Press Vol Down/
Access Disable
2
Intcm/Acc D LED
should Flash yellow.
3
PA Full LED should
NOT illuminate.
4