User's Manual

37
GETTING STARTED
User Guide
REPEATER PROGRAMMING DEFAULT
VALUES
"Programmable Features Default Values" on
page 37 shows the default factory values that the
repeater has pre-programmed. These values can
only be customized by using the CPS software.
Table 6: Programmable Features Default Values
Repeater Features Default Values
Feature Values Default
TX Timeout 1, 2 or 3 minutes 1 minute
TX Hangtime
(or Carrier
Delay)
Off to 50 seconds 5 seconds
Courtesy Beep ON or OFF OFF
Repeater ID
15 minutes, 30
minutes, after TX
hangtime, or OFF
15 minutes
On Battery
Back-Up
OFF, 15 minutes, 30
minutes, 45
minutes, 60 minutes
30 minutes
Low Battery TX 0 to 255 minutes 10 minutes
Number of
Channels
1 to 16 16
Reverse Burst 180 to 240 180
TX Power
Low (2 W) or High
(4 W)
High – 4 W
TX BW 12.5 or 25.0 KHz 12.5 KHz
RX BW 12.5 or 25.0 Khz 12.5 KHz