9-38 December 1, 2000 68P81093C75-O
If the alignment frequency (calculated in the previous
section) is greater than 148 MHz (Range 1), or
greater than 156 MHz (Range 2), turn the five tuning
screws in (clockwise) until 1/8" protrudes past each of
the tension nuts.
If the alignment frequency is less than, or equal to 148
MHz (Range 1), or 156 MHz (Range 2), back out
(counterclockwise) the five tuning screws until 3/4"
protrudes past each of the tension nuts.
Step 5. Using the torque driver and deep-well socket, tighten
the five tension nuts on the adjustment screws to
6 in. – lb.
Step 6. Connect the test equipment as shown in Figure 12.
VHF Tuning Procedure Step 1. Provide power to the PDR 3500 through either DC or
AC (to provide the active 50 termination).
Step 2. Adjust the signal generator to the frequency calculated
on page 36. Set the level to +5 dBm.
Figure 12 Test Equipment Setup for Preselector Field Tuning
Tension Nut
Tuning Screw
To Dip/Peak
Monitor
(RF Millivoltmeter
or Power Meter)
From
Signal
Generator
Tuning
Probe
To
Receiver
Board
To RX
Connector
on Top Panel
Preselector
Assembly
RX
TX
MAEPF-27038-O