User's Manual
PMP320HDW2v1
5-15
Pr
e
limin
a
r
y
J
UL
2
0
1
0
PMP
320
Hardware
Installation
Installing
the
600SSD
Surge
Suppressor
Installing
the
600SSD
Surge
Suppressor
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Use
the
following
procedure
to
install
the
600S
SD
Surge
suppressor
.
CAUT
I
ON
Observe
caution
when
drilling
through
the
wall
of
the
building.
Ensure
that
there
are
no
power
lines,
gas
lines,
water
lines,
or
data
lines
in
the
wall
at
the
desired
location
where
the
drilling
takes
place.
Procedure
5-9
Installing
the
600SSD
Surge
Suppressor
1
W
ith
the
cable
openings
facing
downward,
install
the
600S
SD
surge
suppressor
above
the
site
where
the
hole
in
the
residence
has
been
drilled.
Use
two
screws
to
attach
the
unit
following
regulatory
building
guidelines.
2
Connect
the
surge
suppressor
to
Earth
Ground.
Refer
to
Connecting
the
CSM
to
the
Ethernet
cable,
Earth
Ground,
the
Surge
Suppressor
on
page
6-
13
.
Refer
to
Figure
6-7
.
3
P
ack
both
of
the
600S
SD
surge
suppressor
Ethernet
jacks
with
dielectric
grease.
4
Include
a
splicing
loop
in
the
Ethernet
cable
from
the
CSM
(extra
cable
to
allow
future
repositioning
or
reconnectorization)
and
position
and
secure
the
Ethernet
cable
with
UV
-resistant
wire
ties
or
other
locally-approved
fasteners
so
it
forms
a
drip
loop
(so
water
drips
off
the
cable
instead
of
following
the
cable
into
the
600S
SD
surge
suppressor).
5
Connect
the
Ethernet
connection
from
the
CSM
to
the
surge
suppressor
.
6
Build
another
Ethernet
cable
to
span
from
the
surge
suppressor
through
the
residence
wall
to
the
area
where
the
power
injector
will
be
placed
in
the
subscriber’s
residence.
7
Guide
the
Ethernet
cable
through
the
grommet
where
the
drilled
hole
was
made
into
the
residence.
8
Seal
the
cable
entry
point
into
the
building
using
accepted
industry
or
local
practices.
9
Connect
the
Ethernet
cable
to
the
Data
In
port
of
the
CSM
power
injector
.
Refer
to
Figure
6-8
.