User's Manual
3-34
PMP320HDW2v1
Preliminary
JUL
2010
PMP
320
Hardware
Installation
Surge
Suppressors
Surge
Suppressors
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
The
outdoor
mounting
of
the
CMM4
requires
the
600S
SD
,
200S
SB,
and
in
certain
cases
the
LCOM
surge
suppressor
.
The
L
-
COM
surge
suppressor
is
used
only
if
the
Gigabit
Ethernet
port
is
being
used
on
the
CMM4
switch.
The
L
-
COM
surge
suppressor
can
be
installed
in
the
CMM4
unit.
The
overall
installation
instructions
are
as
follows:
•
ground
the
600S
SD
and
the
200S
SB
to
Earth
Ground
•
connect
the
protected
side
of
the
200S
SB
to
the
AC
power
supply
SGPN4076
•
connect
the
protected
side
of
the
600S
SD
to
the
network
switch
or
router
in
the
communications
hut.
•
add
drip
loops
at
any
point
in
the
cabling
where
the
cable
changes
direction.
NOTE
Additional
L
-
COM
considerations
during
installation:
if
the
CMM4
unit
is
mounted
on
the
antenna
and
is
located
more
that
three
feet
away
from
the
communications
hut,
an
additional
L
-
COM
surge
suppressor
must
be
installed.
Figure
3-2
600SSD
surge
suppressor
connectors
Surge
Suppressor
All
cables
must
exit
through
the
allocated
slots
600SSD
and
200SSB
Surge
Suppressor
installation
Use
the
following
procedure
to
install
the
600S
SD
and
the
200SB
surge
suppressors.