User's Manual
6-14
PMP320HDW2v1
Pr
e
limin
a
r
y
J
UL
2
0
1
0
Ethernet
Cable
Assembly
Chapter
6:
Connectorized
CSM
Hardware
Installation
Procedure
6-8
Connecting
the
Ethernet
cable
to
the
CSM
1
Cut
the
required
length
of
the
outdoor-rated
Category-5
Ethernet
cable
for
the
chosen
installation
site.
The
maximum
cable
length
is
100
m
(~330
ft).
2
T
erminate
the
cable
using
standard
RJ–45
connectors
using
the
procedure
as
shown
in
Figure
6-6
.
Use
dielectric
grease
(which
is
uniformly
non-conducting)
on
all
connections
and
in
all
RJ–45
Ethernet
connectors.
The
best
practice
is
to
use
enough
grease
to
fill
the
RJ–45
female
connector,
and
then
insert
the
RJ-45
male
connector
and
push
the
grease
further
into
the
unit
and
around
the
RJ–45
connector.
Excess
grease
can
be
wiped
over
the
connector
area
to
provide
some
resistance
to
water
ingress
around
the
connector.
3
W
rap
a
drip-loop
in
the
cable
at
any
point
where
the
cable
changes
direction.
4
Measure
the
cable
so
it
will
span
from
the
CSM
to
the
surge
suppressor
box.
5
F
asten
the
cable
to
the
building
according
to
local
building
codes.
NOTE
Cables
that
move
in
the
wind
can
be
damaged,
impart
vibrations
to
the
connected
device,
or
both.
A
t
installation
time,
prevent
these
problems
by
securing
all
cables
with
cable
ties,
cleats,
or
weather
resistant
tape.
The
cable
can
be
a
path
for
water
to
follow
to
enter
the
cable
connector
or
even
the
module.
Prevent
this
problem
by
including
and
securing
a
drip
loop
where
the
cable
enters
the
building.