User's Manual
Table Of Contents
- 1 Introduction
- 2 Product Description
- 2.1 TECHNOLOGY AND BENEFITS
- 2.2 APPLICATIONS
- 2.3 CONFIGURATION OPTIONS – RF, IP, DFS
- 2.4 POWER AND GROUNDING
- 2.5 ADMINISTRATION SYSTEMS
- 2.6 SPECIFICATIONS
- 2.6.1 Radio specifications (common to all formats)
- 2.6.2 Specifications for PMP 430 SM radio with integrated antenna
- 2.6.3 Specifications for PMP 430 SM radio with optional LENS
- 2.6.4 Specifications for PMP 400 and PTP 200 radio with integrated antenna
- 2.6.5 Specification for PMP 400 and 430 connectorized radio
- 2.6.6 Specifications for PMP 400/430 kitted, connectorized radio (antenna included)
- 2.7 PERFORMANCE
- 3 Planning
- 4 Configuring
- 4.1 LINK OPERATION – 1X/2X/3X
- 4.2 TRANSMITTER OUTPUT POWER (AND NO JITTER)
- 4.3 DOWNLINK DATA %, RANGE, AND CONTROL SLOTS
- 4.4 DFS AND REGULATORY PARAMETERS FOR 5.8 & 5.4 GHZ RADIOS
- 4.5 NET ANTENNA GAIN FIELD
- 4.6 NETWORK CONTROL PARAMETERS
- 4.7 FORWARD ERROR CORRECTION
- 4.8 CYCLIC PREFIX (CONFIGURABLE ONLY ON PTP 200 BH & PMP 430 AP/SM)
- 5 Installation
- 6 Regulatory and Legal Notices
- 6.1 IMPORTANT NOTE ON MODIFICATIONS
- 6.2 NATIONAL AND REGIONAL REGULATORY NOTICES
- 6.2.1 U.S. Federal Communication Commission (FCC) Notification
- 6.2.2 Industry Canada (IC) Notification
- 6.2.3 Regulatory Requirements for CEPT Member States (www.cept.org)
- 6.2.4 Equipment Disposal
- 6.2.5 EU Declaration of Conformity for RoHS Compliance
- 6.2.6 Luxembourg Notification
- 6.2.7 Czech Republic Notification
- 6.2.8 Greece Notification
- 6.2.9 Brazil Notification
- 6.2.10 Labeling and Disclosure Table for China
- 6.3 EXPOSURE SEPARATION DISTANCES
- 6.4 LEGAL NOTICES
- 6.5 LIMIT OF LIABILITY
PMP 400/430 and PTP 200 Series Canopy User Guide
Supplement
Issue 4 0 – DRAFT 6 November 2009 Page 57 of 64
6.2.2 Industry Canada (IC) Notification
For 5.4-GHz devices:
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired operation.
Users should be cautioned to take note that in Canada high power radars are allocated as
primary users (meaning they have priority) of 5650 – 5850 MHz and these radars could cause
interference and/or damage to license-exempt local area networks (LELAN).
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to RSS-210 of Industry Canada. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio-frequency energy and, if not installed and used in accordance with
these instructions, may cause harmful interference to radio communications. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment on and off, the user is encouraged to correct the interference by one or
more of the following measures:
• Increase the separation between the affected equipment and the unit;
• Connect the affected equipment to a power outlet on a different circuit from that
which the receiver is connected to;
• Consult the dealer and/or experienced radio/TV technician for help.
To reduce potential radio interference to other users, the antenna type and its gain should be
chosen so its Equivalent Isotropic Radiated Power (EIRP) is not more than that permitted for
successful communication.
This device has been designed to operate with the antennas listed in
Table 13 and having a
maximum gain as shown in
Table 13. Antennas not included in Table 13 or having a gain greater
than as shown in
Table 13 are strictly prohibited from use with this device. Required antenna
impedance is 50 ohms.
For 4.9-GHz devices:
The 4.9-GHz band is a licensed band allocated to public safety services. State and local
government entities that provide public safety services are eligible to apply for 4.9 GHz licenses.
For additional information, refer to Industry Canada regulations.
Industry Canada Certification Numbers and the specific configurations covered are listed in
Table
13.
6.2.3 Regulatory Requirements for CEPT Member States (www.cept.org)
When operated in accordance with the instructions for use, Motorola Canopy Wireless equipment
operating in the 5.4 GHz bands is compliant with CEPT Recommendation 70-03 Annex 3 for
Wideband Data Transmission and HIPERLANs. For compliant operation in the 5.4 GHz band, the
transmit power (EIRP) from the integrated antenna or a connectorized antenna shall be no more
than 0.5 W (27 dBm).
For EU member states, RLAN equipment in the 5.4GHz bands is exempt from individual licensing
under Commission Recommendation 2003/203/EC. Contact the appropriate national
administrations for details on the conditions of use for the bands in question and any exceptions
that might apply. Also see www.ero.dk for further information.
10 MHz channels are used, centered on 5475 to 5595 and 5655 to 5715 in 5 MHz increments.
This is within the 5470 to 5725 MHz U-NII band with 5600 to 5650 MHz excluded.