User's Manual
Table Of Contents
- 1 Introduction
- 2 Product Description
- 2.1 TECHNOLOGY AND BENEFITS
- 2.2 APPLICATIONS
- 2.3 CONFIGURATION OPTIONS – RF, IP, DFS
- 2.4 POWER AND GROUNDING
- 2.5 ADMINISTRATION SYSTEMS
- 2.6 SPECIFICATIONS
- 2.6.1 Radio specifications (common to all formats)
- 2.6.2 Specifications for PMP 430 SM radio with integrated antenna
- 2.6.3 Specifications for PMP 430 SM radio with optional LENS
- 2.6.4 Specifications for PMP 400 and PTP 200 radio with integrated antenna
- 2.6.5 Specification for PMP 400 and 430 connectorized radio
- 2.6.6 Specifications for PMP 400/430 kitted, connectorized radio (antenna included)
- 2.7 PERFORMANCE
- 3 Planning
- 4 Configuring
- 4.1 LINK OPERATION – 1X/2X/3X
- 4.2 TRANSMITTER OUTPUT POWER (AND NO JITTER)
- 4.3 DOWNLINK DATA %, RANGE, AND CONTROL SLOTS
- 4.4 DFS AND REGULATORY PARAMETERS FOR 5.8 & 5.4 GHZ RADIOS
- 4.5 NET ANTENNA GAIN FIELD
- 4.6 NETWORK CONTROL PARAMETERS
- 4.7 FORWARD ERROR CORRECTION
- 4.8 CYCLIC PREFIX (CONFIGURABLE ONLY ON PTP 200 BH & PMP 430 AP/SM)
- 5 Installation
- 6 Regulatory and Legal Notices
- 6.1 IMPORTANT NOTE ON MODIFICATIONS
- 6.2 NATIONAL AND REGIONAL REGULATORY NOTICES
- 6.2.1 U.S. Federal Communication Commission (FCC) Notification
- 6.2.2 Industry Canada (IC) Notification
- 6.2.3 Regulatory Requirements for CEPT Member States (www.cept.org)
- 6.2.4 Equipment Disposal
- 6.2.5 EU Declaration of Conformity for RoHS Compliance
- 6.2.6 Luxembourg Notification
- 6.2.7 Czech Republic Notification
- 6.2.8 Greece Notification
- 6.2.9 Brazil Notification
- 6.2.10 Labeling and Disclosure Table for China
- 6.3 EXPOSURE SEPARATION DISTANCES
- 6.4 LEGAL NOTICES
- 6.5 LIMIT OF LIABILITY
PMP 400/430 and PTP 200 Series Canopy User Guide
Supplement
Issue 4 0 – DRAFT 6 November 2009 Page 22 of 64
2.5 ADMINISTRATION SYSTEMS
Standard Canopy administration systems are used to support the PMP 400/430 and PTP 200
Series products. The administration systems must be at the appropriate release level.
The Prizm element management system is used to manage and monitor Canopy modules and to
update module software. Prizm 3.2 with Patch 3 manages and monitors PMP 400/430 and PTP
200 Series modules. Prizm 3.2 software and documentation is available at
http://motorola.wirelessbroadbandsupport.com/software/
.
CNUT 3.20 (Canopy Network Update Tool) is the stand-alone software update tool for PMP
400/430 and PTP 200 Series products for operators not using Prizm. CNUT is available at
http://motorola.wirelessbroadbandsupport.com/software/
.
2.6 SPECIFICATIONS
PMP 430 products are sold in the following formats:
• SM - Radio with integrated antenna
• AP - Kitted, connectorized radio (antenna included)
• AP – Connectorized radio (antenna provided by operator)
PMP 400 and PTP 200 products are sold in the following formats:
• SM/BH - Radio with integrated antenna
• AP/SM/BH - Connectorized radio (antenna provided by operator)
• AP - Kitted, connectorized radio (antenna included)
The following sections list specifications for each format.
2.6.1 Radio specifications (common to all formats)
Radio
Type
Frequency
Settable Transmit (Tx)
Output Power Range
Default Tx
Power
AP 5.8 GHz -30 to +20 dBm +16 dBm
AP/BH 5.4 GHz -30 to +10 dBm +10 dBm
AP/BH 4.9 GHz -30 to +18 dBm +18 dBm
SM
5.8 GHz
SM Auto TPC* 5.4 GHz
4.9 GHz
* SMs use Auto TPC (Transmit Power Control), with power set
by the AP to provide power leveling for close-in SMs
• Under 13 W DC power
• Environment range of -40°C to +55°C (-40°F to +131°F); 0 to 95% relative humidity,
non-condensing
• PMP 400/430 and PTP 200 products are available with either DES or AES encryption