User's Guide

Table Of Contents
Chapter 31
Trunking System Control
This feature allows your radio to communicate the trunking status when on a trunking channel
Your radio can communicate different types of trunking statuses.
Table 25: Types of Trunking System Status
Types Description
Out of Range
When your radio goes out of the range, it
can no longer lock onto a control channel.
You hear a low-pitched tone, and or the
display shows the currently selected zone
or channel combination, and Out of range
notification. Your radio remains in this out-of-
range condition until it locks onto a control
channel, or if it is turned off.
Site Trunking
5
If the Trunk Controller loses communication
with any site, that site reverts to site trunk-
ing. When this occurs, you can communicate
only with the radios within your trunking site.
Affiliation Failed
Affiliation failed is when the radio is success-
fully locked and registered to a site, but fails
to affiliate to Unified Knob Position (UKP).
Your radio displays failed message, the site
alias, and the UKP alias.
Registration Denied
Registration denied is when your radio regis-
tration is denied on a site.
Your radio displays failed message and the
UKP alias.
31.1
Viewing RSSI Value
Procedure:
Press the 2-Dot Programmable Feature button five times.
The top display shows the RSSI value.
5
Only applicable to Capacity Max System.