User's Manual

Appendix C: The AMR ToolBox
32
If the transmitter parameters are changed once it is
operational, the meter readings should be recorded, as
described in the Recording Counter Values/Readings
section of the Installation chapter above, to ensure data
collection integrity.
Enabling the Transmitter
To enable the transmitter,
1. Click on the Enable Transmitter button in the
Transmitter Status tool.
!
C a u t i o n
Once the AMR transmitter is enabled, it cannot be
disabled. Do not enable the AMR transmitter if it is
to be transported by air.
2. Select the Transmitter Status tool.
3. Click on the Enable Transmitter button.
4. The results (either Succeeded or Failed) will appear on
the screen.
5. To check the status, click on the Upload button.
6. The status (either Enabled or Disabled) will appear on
the screen.
Testing the Transmitter
To test if the transmitter is operational using the AMR
ToolBox,
1. Select the Transmitter Hardware Test tool.
2. Click on the Comm Test tab.
3. Click on the Start button.
4. Verify the OK/Fail status in the Test Result on the
screen.