User's Manual
Table Of Contents
Installation
8
With the AMR ToolBox
The transmitter can be enabled and tested using the AMR
ToolBox.
1. Connect the transmitter to the programmer unit as
shown in Figure 11 in Appendix C.
2. Place the magnet for more than 10 seconds near the
top of the transmitter and remove it. This will put the
transmitter into programming mode.
3. Select the Transmitter in the AMR ToolBox menu
panel and click on the Connection Check icon in the
icon bar (or select the Connection Check command
from the Comm menu.)
4. If the connection fails, repeat step 2. If the connection
still fails, switch to the Repeater in the AMR ToolBox
menu panel and repeat the Connection Check. If this
too fails, check the physical connection and COM port
setting of the programmer and the ToolBox PC. If the
repeater connection now succeeds, repeat step 2. If the
transmitter connection still fails, check the physical
connection between the programmer and the
transmitter.
5. If the connection succeeds, click on the Enable
Transmitter button in the Transmitter Status tool to
enable the transmitter.
6. If the screen shows that the Transmitter is enabled,
click TX check on the Comm Test tab of the HW Test
tool to test the transmission. If the TX check succeeds,
OK will be displayed in the tool window.
7. If the screen shows that the Transmitter is disabled,
click on the Enable Transmitter button. If it still fails,
enable the transmitter as described in Without the
AMR ToolBox again. If this too fails, replace the unit.
For more information on the AMR ToolBox, see Appendix
C below and the AMR ToolBox User Guide.