Users Manual Part 2
Alarm ID
Descrip-
tion
Recovery
Action
Clear Ac-
tion
Notes
able to re-
ceive.
er is re-ena-
bled by the
software.
failure or config-
uration prob-
lems.
ALM_RX_ABACUS_LO2_SL Receiver
main Aba-
cus 2nd LO
failure.
Receiver is
disabled by
the software
- BRC is un-
able to re-
ceive.
If the alarm
condition
disappears
then Receiv-
er is re-ena-
bled by the
software.
The alarm may
be reported be-
cause of the
BRC hardware
failure or config-
uration prob-
lems.
ALM_RX_ABA-
CUS_2LO_SL_FAIL
Reported when ALM_RX_ABACUS_LO2_SL is set and
ALM_RX_5_VOLT is cleared
• ALM_BRC_ABA-
CUS_CLK1_ALM
• ALM_BRC_ABA-
CUS_CLK1_FAIL
Abacus
clock 1 is
not present
- the alarm
is reported
as a fault in-
dication
message
from DSP.
BRC is de-
keyed by the
software.
The alarm is
cleared just
after BRC is
de-keyed.
The alarm may
be reported be-
cause of the
BRC hardware
failure.
• ALM_BRC_ABA-
CUS_CLK2_ALM
• ALM_BRC_ABA-
CUS_CLK2_FAIL
Abacus
clock 2 is
not present
- the alarm
is reported
as a fault in-
dication
message
from DSP.
BRC is de-
keyed by the
software.
The alarm is
cleared just
after BRC is
de-keyed.
The alarm may
be reported be-
cause of the
BRC hardware
failure.
•
ALM_BRC_ABA-
CUS_CLK3_ALM
• ALM_BRC_ABA-
CUS_CLK3_FAIL
Abacus
clock 3 is
not present
- the alarm
is reported
as a fault in-
dication
message
from DSP.
BRC is de-
keyed by the
software.
The alarm is
cleared just
after BRC is
de-keyed.
The alarm may
be reported be-
cause of the
BRC hardware
failure.
• ALM_BRC_ABA-
CUS_FS1_ALM
• ALM_BRC_ABA-
CUS_FS1_FAIL
Abacus
frame sync
1 is not
present -
the alarm is
reported as
a fault indi-
cation mes-
sage from
DSP.
BRC is de-
keyed by the
software.
The alarm is
cleared just
after BRC is
de-keyed.
The alarm may
be reported be-
cause of the
BRC hardware
failure.
6802800U74-AP