Users Manual Part 2
13.2.1.1
Base Radio Alarms
The following table displays the generic base radio alarms that can be listed using MMI command get
alarms.
Table 110: Generic Base Radio Alarms
Alarm ID
Descrip-
tion
Recovery
Action
Clear Ac-
tion
Notes
• ALM_BRC_NVM_CKSUM
_FAULT
• ALM_BRC_NVM_CKSUM
_FAIL
Checksum
fault for the
XCVR NVM
parameters
was detec-
ted during
initialization
- some of
the XCVR
configura-
tion param-
eters may
be corrup-
ted.
Software at-
tempts to set
the parame-
ters to the
default val-
ues taken
from the de-
fault region
in the NVM
memory.
If the opera-
tion of re-
storing de-
faults is suc-
cessful the
alarm is
cleared. Oth-
erwise the
alarm status
is un-
changed.
Corrupted con-
figuration pa-
rameters may
cause that BRC
works incorrect-
ly. The default
values may be
different than the
lost parameter
values. To en-
sure that the pa-
rameters can be
restored man-
ually to the earli-
er backed up
values.
• ALM_BRC_16_8MHZ_FAI
L_ALM
• ALM_BRC_16_8MHZ_FAI
L
The
16.8MHz
reference
failure - this
alarm origi-
nates from
the VCXO
and it is re-
ported by
the interrupt
(Host
IRQ4).
BRC is de-
keyed by the
software.
The alarm is
cleared only
after reset-
ting BRC.
The alarm may
be reported be-
cause of the
BRC hardware
failure.
ALM_RX_LO1_LOCK Receiver
synthesizer
lock detect
failure.
Receiver is
disabled by
the software
- BRC is un-
able to re-
ceive.
If the alarm
condition
disappears
then Receiv-
er is re-ena-
bled by the
software.
The alarm may
be reported be-
cause of the
BRC hardware
failure or be-
cause RX VCO
is not properly
tuned (BCD
NVM parame-
ters configura-
tion).
ALM_RX_SYNTH_LD_FAIL
Reported when ALM_RX_LO1_LOCK is set and
ALM_BRC_16_8MHZ_FAIL_ALM is cleared
6802800U74-AP
Chapter 13: MTS Troubleshooting
401