Users Manual Part 2
13.1.2.1
Troubleshooting Flow Chart
Figure 191: Troubleshooting Flow Chart
Start
Check Power
LED
Are LEDs Stuck
ON
Is MMI
Available?
Application mode
MMI available
See “Troubleshooting power” section
Off
On
Yes
Yes
Yes
No
No
No
Replace faulty TSC. TSC boot
software fails to execute and
turn software controlled LEDs off.
Check MMI cable,
and terminal set-up.
See chapter “Configuration and
Testing”
Check/reinstall TSC Application
using BTS
Service Software
See “Troubleshooting: General”
See “Led Fault Indication” section
13.1.2.2
Troubleshooting: Power
• Check for Power Supply Unit failure.
• Verify power (voltage and polarity) on rear connector. If power is present and correct then replace
the Site Controller. Otherwise check for the Site Controller power supply cabling fault.
NOTICE: Ensure that the polarity of DC cable connection is correct, as it is reversed in
comparison to MBTS.
13.1.2.3
Troubleshooting: status sc
This section details usage of the Application mode MMI command status sc for general
troubleshooting and to determine the Site Controller status.
6802800U74-AP
Chapter 13: MTS Troubleshooting
377