Users Manual Part 2

Unit Function
NOTICE: See the MMI Commands manual for additional informa-
tion on commands and parameters.
ATCC Monitoring:
Cavity status.
ATCC Heartbeat signal: heart beat signal is repeated every 30 s.
Alarms:
Software corrupted.
Distance between two channels below 150 kHz.
Cavity VSWR alarm.
Master Slave communication error.
Motor alarm.
Cavity tuning error alarms together.
VSWR exceeded the specified value.
Unable to park cavity.
Cavity unable to tune to the current frequency in 3 attempts.
Controls:
Cavity tune timeout: establishes a timeout period between a fine-tuning of
the cavities. All cavities must be fine-tuned at the timeout.
Park a cavity: instructs the ATCC to park the specified cavity. This in-
volves adjusting the cavity resonance to a frequency outside of the Tx
band. If RF power is present, the cavity parks and then re-tunes to the in-
put frequency.
VSWR Alarm Threshold: establishes a threshold for enabling a VSWR
Alarm. Valid threshold values are in the range 1.00 to 10.00 where 1.00
means No VSWR.
Recommended values for each MTS configuration are:
- 400 MHz: 3.00
- 260 MHz: 3.00
- 800 MHz: 4.00
DPM (Duplexer,
Post Filter)
Monitoring:
Forward power on a digital power monitor: the input power range is from
0 W to 150 W.
Reverse power on a digital power monitor: the input power range is from
0 W to 40 W.
VSWR from a DPM.
DPM temperature.
DPM Heartbeat signal.
Alarms:
SW is corrupted or unable to initialize.
6802800U74-AP
Chapter 8: Site Controller