Users Manual Part 2

8 Connect the Ethernet cables previously attached to the Base Radio(s) to the Site Controller.
Also connect the newly added Site Controller to the junction panel according to the scheme
below:
Part no Cable type From To
3066543B10 RF Cable Junction Panel / E1 Y splitter
3066560B01 Y splitter SC1 / E1
3066567B02 Y splitter SC2 / E1
9 Connect RF cable 3066543B10 to GPS connector.
10 Connect the redundant control signal cable according to the scheme below:
Part no Cable type From To
3066544B17 Redundant CTRL
signal cable
SC1 / RedIn SC2 / RedOut
3066544B17 Redundant CTRL
signal cable
SC1 / RedOut SC2 / RedIn
NOTICE: Make sure to follow the color indications on both the cables as well as on the
Site CONTROLLER.
11 Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN
Bus cable according to the scheme below:
Part no Cable type From To
3066544B03 CAN Bus cable SC2 / CAN PSU2 / CAN2
12 Connect the power cables to the MTS Power Supply Units.
15.4.2
Configuring Redundant Site Controller
NOTICE: Redundant Site Controller feature is supported by MTS Software releases:
MTS SPU R5.2_002.34 or later
MTS SPU R6.0_001.12 or later
NOTICE: On power up of the Standby Site Controller the Base Radios may dekey and reset.
Base Radios will automatically recover and key up again within 20 seconds.
Process:
1 Perform Site Controller Hardware Pre-Checks.
See Performing Site Controller Hardware Pre-Checks on page 465.
2 Configure the Site Controller Configuration Files.
See
Configuring Site Controller Configuration Files on page 465.
3 Configure Ethernet ports connecting the two Site Controllers.
See Configuring Ethernet Ports on page 465.
4 Configure the ID values of the Site Controllers.
See Configuring Site Controller IDs on page 467.