Users Manual Part 2
For detailed procedures, see the respective restoration manual (DIPS/DIPC/X Core systems) or
Service Manual (DIPM system).
6 Load Ki’s into MTS.
See the respective restoration manual (DIPS/DIPC/X Core systems) or Service Manual (DIPM
system) for details on loading Ki's Into MTS.
7 Check the MTS post-restoration checks.
For details, see the respective restoration manual (DIPS/DIPC/X Core systems) or Service
Manual (DIPM system).
IMPORTANT:
When adding a second Site Controller it will automatically become standby meaning that
performance of Site Controller post-restoration checks will not be possible.
In order to perform a Site Controller Post-restoration check on the second Site Controller,
the first Site Controller needs to be reset allowing the second Site Controller to become
active leading to interruption of service for several seconds.
8 Configure Redundant Site Controller feature.
See Configuring Redundant Site Controller on page 464.
15.4.1.1
Installing a Second Site Controller
Procedure:
1 Wear an ESD strap and connect its cable to a verified good ground. This strap must be worn to
prevent ESD damage to any components.
2 Remove the Site Controller Blind Plate.
3 Label the cables with labels included in the expansion kit.
4 Connect the Ethernet cables to the Base Radio(s) according to the scheme below:
Part no Cable type From To
3066544B02 Ethernet cable
SC2 / BR4 BR4 / SC2
3066544B15 Ethernet cable SC2 / BR1 BR1 / SC2
3066544B16 Ethernet cable SC2 / BR2 BR2 / SC2
3066544B01 Ethernet cable SC2 / BR3 BR3 / SC2
NOTICE: At this stage only connect the cables to the Base Radios.
5 Strap the cables. Connect RF cable 3066543B10 to the GPS2 connector on the Junction Panel
and let it hang. Catch the cable in the empty space where the Site Controller is to be assembled
and temporarily fix it at the front.
6 Install the Site Controller. Use the handle to slide the unit into the chassis.
IMPORTANT: Connect the ribbon cables at the rear before sliding the unit into the
chassis. Be careful not to damage the cables when sliding the Site Controller into place.
7 Secure the Site Controller in the chassis with two M4X10 captive screws.
6802800U74-AP
Chapter 15: Expansion Options
463