Users Manual Part 2

Ethernet cables from Base Radio(s) in lower Module Cage to SC in upper Module Cage
(SC2).
Ethernet cables from Base Radio(s) in upper Module Cage to SC in lower Module Cage
(SC1).
CAN Bus cables to and from Filters.
3 Connect the Rx cables to the filters and let them hang on the back side behind Cavity
Combiners that may exist in configuration.
4 Connect the AC Power cable (3066553B01), the DC Power cable (3066553B01) and the Battery
Sensor cable (3066556B02) to the adequate connectors on the Junction Panel and let them
hang on the back side behind Cavity Combiners that may exist in configuration.
5 Catch Rx cables, AC Power cable, DC Power cable and Battery Sensor cable in the empty
space where new module cage is to be assembled and temporarily fix them at the front.
6 Assemble the Air Separator shelf above the existing Module Cage. Use four M6x16 screws
included in the expansion kit.
7 Assemble the new Module Cage on top of the Air Separator shelf. Use eight M6x16 screws
included in the expansion kit.
NOTICE: You may have to temporarily remove the fans in order to fasten the screws.
8 If applicable, remove the Power Supply Unit Blind Plate.
NOTICE: If Power Supply Unit has been pre-assembled in your configuration, jump
directly to Step 8.
9 Place the Power Supply Unit on the slide rails in the Module Cage and push it to the back.
10 Secure the Power Supply Unit to the Module Cage with the two M4x10 Torx screws and lock the
washers.
11 Connect the power supply cables and optional backup battery cables according to the scheme
below:
Part no Cable type From To
3066551B01 DC Power Ca-
ble
Junction panel / DC2
PSU2 / DC In
3066553B01 AC Power Ca-
ble
Junction panel / AC In 2
PSU2 / AC In
3066556B02 Batt Sens cable Junction panel / Bat
Temp 2
PSU2 / Battery Temp.
Sens.
3066545B01 DC Power Ca-
ble
BR3 / DC In
PSU2 / DC Out
BR4 / DC In
Site Controller / Power
NOTICE: If Base Radio being added is the second Base Radio in a Module Cage (BR2
or BR4), DC Power Cable (3066545B01) is already existing in configuration.
12 Connect the RJ45 cable according to the scheme below:
Part no Cable type From To
6802800U74-AP
Chapter 15: Expansion Options
452