Users Manual Part 2

4 3066543B12 BR1 / TX Hybrid Combin-
er / TX A
Existing cable previously
unplugged from the Du-
plexer
8 3066543B05 BR2 / TX Hybrid Combin-
er / TX B
9 3066543B06 Hybrid Combin-
er / TX Out
Duplexer / TX
NOTICE: Index numbers in table above refer to cable connections shown in Figure 197:
RF Cabling Diagram for MTS 2 with one TX/RX ant. and up to two RX ant. after
Expansion on page 447.
9 Switch ON the Power Supply Unit.
15.1.3
Configuration
When the additional Base Radio has been installed properly it needs to be configured and verified. In
order to do so, follow Configuring and Verifying the Base Radio on page 251.
In addition to this, the following parameters need to be configured in TESS application:
Factory password
Field password
Cabinet ID
Position ID
Carrier Number (TX/RX frequencies are auto-generated based on Carrier Number setting)
Default TX Power level
NOTICE: When these parameters have been configured in TESS Application and after the
modified configuration file has been uploaded to the Site Controller, the complete site needs to
be reset to implement the configuration change.
15.2
Additional Module Cage for MTS 4
It is possible to complement MTS 4 with additional module cage.
NOTICE: The module cage for MTS 4 is delivered with the expansion kit that includes required
equipment and cables.
15.2.1
Adding an Additional Module Cage to MTS 4
Follow the procedure below to add a second module cage to the MTS 4 cabinet.
Procedure:
1 Remove the Module Cage Beauty Plate.
2 Mount all cables going from the lower Module Cage in your specific configuration and fix them
temporarily in the rack before mounting the air divider and module cage.
NOTICE: This would typically be:
6802800U74-AP
Chapter 15: Expansion Options
451