Users Manual Part 2

Ship defective modules to a Motorola Solutions repair depot for repair.
This manual provides two troubleshooting procedures for the Base Radio. Each procedure is designed
to quickly identify faulty modules.
13.2.1.4
Routine Checkout
Procedure 1 is a quick, non-intrusive test performed during a routine site visit. Use this procedure to
verify proper station operation without taking the station out of service. The following figure shows the
Procedure 1 Troubleshooting Flowchart.
Figure 192: Procedure 1 Troubleshooting Flowchart
PROCEDURE 1
ROUTINE
SITE VISIT
OBSERVE LED
INDICATORS
Module Suspected
of Being Faulty?
No
No
DONE
CHECK CURRENT
ALARM STATUS
Use MMI command
get alarms
to check alarm status
Module Suspected
of Being Faulty?
Ye s
Go to Troubleshooting
Procedure 2 Flow Chart
Ye s
Go to Troubleshooting
Procedure 2 Flow Chart
Refer to
Controls and Indicators
for LED Definitions
EBTS021
071895JNM
6802800U74-AP
Chapter 13: MTS Troubleshooting
423