Users Manual Part 1
Figure 21: MTS Mounting Plate
The mounting plate is normally secured directly to the floor.
NOTICE: The use of an insulated base may be considered where additional lightning protection
is required or where local regulations require this (see R56 Manual for further information).
4.4.4.2
Installing the Mounting Plate
When and where to use: Perform this procedure to properly install the mounting plate within the site
facility.
Procedure:
1 Ensure that the mounting plate has been correctly positioned in the equipment room, see Figure
7: Suggested MTS LiTE Site Layout on page 66 for MTS LiTE, Figure 9: Suggested MTS 2 Site
Layout on page 68
for MTS 2, Figure 11: Suggested MTS 4 Site Layout on page 70 for MTS 4,
and Figure 13: Suggested Expansion Cabinet Site Layout on page 72 for Expansion Cabinet.
6802800U74-AP
Chapter 4: Hardware Installation
98