Users Manual Part 1
3.7.2.1.5
Power Loads and Heat Dissipation – MTS 800 MHz / 900 MHz
Table 17: Typical Power Loads and Heat Dissipation Values – MTS 800 MHz / 900 MHz Configuration
MTS 800 MHz/
900 MHz Config-
uration
AC
(W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat AC
When
Charg-
ing (W)
DC
-48
V
(W)
Heat
DC
(W) Comment
TETRA TX 10 W
MTS LiTE and
MTS2 with 1 BR
280 270 660 325 215 205 No combining,
high power PA,
fans
MTS2 with 1 BR
w. Hybrid
320 310 705 370 235 225 High power PA,
fans
MTS2 with 2 BRs 445 425 825 480 315 295 Two TX ant.,
low power PA,
fans
MTS2 with 2 BRs
w. Hybrid
530 510 915 570 365 345 High power PA,
fans
MTS4 with 1 BR
w. MTCC/ATCC
320 310 705 370 235 225 High power PA,
fans
MTS4 with 2 BRs
w. MTCC/ATCC
530 510 915 570 365 345 High power PA,
fans
MTS4 with 3 BRs
w. MTCC/ATCC
855 825 1620 940 605 575 High power PA,
fans
MTS4 with 4 BRs
w. MTCC/ATCC
108
0
1040 1840 1155 745 705 High power PA,
fans
TETRA TX 25 W and TEDS TX 10 W
MTS LiTE and
MTS2 with 1 BR
330 305 715 380 325 300 No combining,
High power PA,
fans
MTS2 with 1 BR
w. Hybrid
405 380 790 455 395 370 High power PA,
fans
MTS2 with 2 BRs 550 500 930 590 540 490 Two TX ant.,
High power PA,
fans
MTS2 with 2 BRs
w. Hybrid
700 650 1085 740 685 635 High power PA,
fans
MTS4 with 1 BR
w. MTCC/ATCC
405 380 790 455 395 370 High power PA,
fans
MTS4 with 2 BRs
w. MTCC/ATCC
700 650 1085 740 685 635 High power PA,
fans
MTS4 with 3 BRs
w. MTCC/ATCC
113
0
1055 1890 1215 110
5
1030 High power PA,
fans
6802800U74-AP
Chapter 3: Site Preparation
85