Users Manual Part 1

MTS 800 MHz
Configuration
AC (W) Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat
AC
When
Charg
ing
(W)
DC-48
V (W)
Heat DC
(W)
Comment
MTS4 with 3 BRs
w. MTCC/ATCC
655 625 1420 740 640 610 Fans
MTS4 with 4 BRs
w. MTCC/ATCC
810 770 1575 885 795 755 Fans
TETRA TX 25 W
MTS2 with 1 BR 280 255 660 310 270 245 No com-
bining,
fans
MTS2 with 1 BR
w. Hybrid
400 375 780 430 390 365 Fans
MTS2 with 2 BRs 445 395 825 455 435 385 Two TX
ant, fans
MTS2 with 2 BRs
w. Hybrid
685 635 1070 695 670 620 Fans
MTS4 with 1 BR
w. MTCC/ATCC
375 350 755 410 370 345 Fans
MTS4 with 2 BRs
w. MTCC/ATCC
640 590 1020 650 625 575 Fans
MTS4 with 3 BRs
w. MTCC/ATCC
1040 965 1800 1080 1015 940 Fans
MTS4 with 4 BRs
w. MTCC/ATCC
1320 1220 2085 1335 1290 1190 Fans
3.7.2.1.2
Power Loads and Heat Dissipation – Expansion Cabinet 400 MHz and 800 MHz
Table 12: Typical Power Loads and Heat Dissipation Values – Expansion Cabinet 400 MHz BR-Arch-1
Configuration
Expansion Cabi-
net Consump-
tions MTS 400
MHz Configura-
tion
AC
(W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat AC
When
Charg-
ing (W)
DC
-48
V
(W)
Heat
DC
(W) Comment
TETRA TX 10 W
MTS4 Exp. Cab.
w 1 BR w. MTCC/
ATCC
240 230 625 290 235 225 Low power PA,
fans
MTS4 Exp. Cab.
w. 2 BRs w.
MTCC/ATCC
375 355 755 410 365 345 Low power PA,
fans
6802800U74-AP
Chapter 3: Site Preparation
80