Users Manual Part 1

MTS 400 MHz
Configuration
AC
(W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat AC
When
Charg-
ing (W)
DC
-48
V
(W)
Heat
DC
(W) Comment
MTS4 with 3 BRs
w. MTCC/ATCC
103
5
960 1800 1075 101
0
935 Fans
MTS4 with 4 BRs
w. MTCC/ATCC
132
0
1220 2080 1330 129
0
1190 Fans
TETRA TX 40 W
MTS2 with 1 BR 355 315 735 385 345 305 No combining,
fans
MTS2 with 2 BRs 595 515 975 385 580 500 Two TX ant., no
combining. fans
NOTICE:
All the values in the table are calculated from AC = 230 V
Add additional 5% for 110 V
Charging is up to 6 A per PSU
Table 11: Typical Power Loads and Heat Dissipation Values – MTS 800 MHz BR-Arch-2
Configurations
MTS 800 MHz
Configuration
AC (W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat
AC
When
Charg
ing
(W)
DC-48
V (W)
Heat DC
(W)
Comment
TETRA TX 10 W
MTS2 with 1 BR 145 135 530 195 145 135 No com-
bining, no
fans
MTS2 with 1 BR
w. Hybrid
185 175 570 235 180 170 No fans
MTS2 with 2 BRs 265 245 645 300 255 235 No com-
bining,
Two TX
ant, no
fans
MTS2 with 2 BRs
w. Hybrid
340 320 725 380 335 315 No fans
MTS4 with 1 BR
w. MTCC/ATCC
255 245 635 300 250 240 Fans
MTS4 with 2 BRs
w. MTCC/ATCC
400 380 780 435 390 370 Fans
6802800U74-AP
Chapter 3: Site Preparation
79