Users Manual Part 1
MTS 400 MHz
Configuration
AC
(W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat AC
When
Charg-
ing (W)
DC
-48
V
(W)
Heat
DC
(W) Comment
MTS4 with 4 BRs
w. MTCC/ATCC
130
0
1200 2065 1375 127
0
1170 High power PA,
fans
Table 10: Typical Power Loads and Heat Dissipation Values – MTS 400 MHz BR-Arch-2
Configurations
MTS 400 MHz
Configuration
AC
(W)
Heat
AC
(W)
AC
When
Charg
ing
(W)
Heat AC
When
Charg-
ing (W)
DC
-48
V
(W)
Heat
DC
(W) Comment
TETRA TX 10 W
MTS2 with 1 BR 140 130 520 185 135 125 No combining,
no fans
MTS2 with 1 BR
w. Hybrid
185 175 565 230 180 170 No fans
MTS2 with 2 BRs 250 230 630 285 240 220 No combining,
Two TX ant., no
fans
MTS2 with 2 BRs
w. Hybrid
335 315 720 375 330 310 No fans
MTS4 with 1 BR
w. MTCC/ATCC
250 240 635 300 245 235 Fans
MTS4 with 2 BRs
w. MTCC/ATCC
390 370 775 430 385 365 Fans
MTS4 with 3 BRs
w. MTCC/ATCC
645 615 1410 730 630 600 Fans
MTS4 with 4 BRs
w. MTCC/ATCC
800 760 1560 875 780 740 Fans
TETRA TX 25 W
MTS2 with 1 BR 280 255 660 310 270 245 No combining,
fans
MTS2 with 1 BR
w. Hybrid
405 380 785 435 395 370 Fans
MTS2 with 2 BRs 445 395 825 450 435 385 Two TX ant,
fans
MTS2 with 2 BRs
w. Hybrid
695 645 1075 700 680 630 Fans
MTS4 with 1 BR
w. MTCC/ATCC
375 350 755 410 365 340 Fans
MTS4 with 2 BRs
w. MTCC/ATCC
640 590 1020 645 625 575 Fans
6802800U74-AP
Chapter 3: Site Preparation
78