Users Manual Part 1
Figure 157: Schematic Diagram of Post Filter
Postfilter
TX
Pwr
meter
Coupler
Detector
A/D
CAN Bus
Ctrl
DC
CAN Bus
To Hybrid, ATCC/
MTCC or BR
2xCAN Bus
7v DC supply
Antenna
7.3.5.1
Replacing the Post Filter
For a list of available FRUs, see Field Replaceable Units (FRUs) on page 478.
Process:
1 Remove the Post Filter, see Removing the Post Filter on page 302.
2 Install the Post Filter into the cabinet, see Inserting the Post Filter into the Cabinet on page 303.
3 Update the mapping list with the new unit TrackID, see Updating the Mapping List with the New
Unit TrackID on page 303.
7.3.5.1.1
Removing the Post Filter
Procedure:
1 WARNING: RF energy hazard and potential equipment damage precaution.
To prevent accidental contact with high energy and injury to personnel, switch off the Power
Supply Unit.
2 Remove the four screws holding the front panel.
3 Loosen the two screws holding the front section of the top panel and slide off the panel.
4 Loosen the screws fastening the rear section of the top panel and slide off the panel.
6802800U74-AP
Chapter 7: Radio Frequency Distribution System
302