Users Manual Part 1

GPS Operating OK is YES
The GPS LED will flash satellite tracking commences and will be fully on, once GPS is fully trained.
If satellite tracking is NOT ADEQUATE, make sure:
The GPS receiver has been allowed enough time to locate the satellites (in extreme cases this may
take up to 2 hours).
The GPS antenna cable is properly connected. If it is not, reconnect the cable properly and then
reset the Site Controller. If cable is found to be properly connected, the GPS antenna is possibly
faulty.
See MTS Troubleshooting
on page 373 for more information on troubleshooting GPS.
CAUTION: Do not attempt to make a resistance check of the GPS antenna. Damage to the
active devices within the antenna element may result.
6.5
Configuring and Verifying the Base Radio
For the Base Radio, there are a number of procedures that you must follow to ensure that it is up and
running.
All module-specific information is programmed in the factory before shipment. Base Radio-specific
parameters (for example, receive and transmit frequencies) are downloaded to the Base Radio from
the network/Site Controller.
Process:
1 Verify the BRC state using the front panel LEDs.
See Base Radio Startup Sequence on page 252.
2 Select Base Radio Position and Receivers Selection.
See Base Radio Position and Receivers Selection on page
253:
Setup and Access to Base Radio Position on page 254
Setting and Accessing Base Radio Position by Using the cccp Command on page 255
Enabling Base Radio Receiver Branches on page 256
Additional Receiver Configuration for BR-Arch-1 on page 256
3 Configure the Base Radio DPM and ATCC mappings to the Site Controller. See Configuring the
pm_config on page 259.
4 Verify the transmit and receive operations.
See Station Verification Procedures on page 260:
Verifying the Base Radio Software Revision on page 260
Verifying the Transmitter on page 263
Receiver Verification on page 265
5 Display outstanding Base Radio alarm conditions.
See Displaying Base Radio Alarms on page 271.
6802800U74-AP
Chapter 6: Configuration and Testing
251