Users Manual Part 1
If… Then…
If you want to log on to the Test Applica-
tion in the BR-Arch-2 architecture,
In the command line enter the command:
testapp
Postrequisites:
NOTICE: To reset Base Radio and return to the default Base Radio application, type reset –
oplatform.
6.2.2
Test Equipment
The following table lists the recommended test equipment for the equipment cabinet procedures.
Equivalent equipment is acceptable.
WARNING: Ensure that the test equipment is connected to the same ground system as the
equipment under test before any other connections are made to the test equipment.
Table 73: Equipment for Cabinet Testing
Equipment Model/Type Manufacturer Description
Service Terminal Locally Pro-
cured
Used to access and inter-
face with Site Controller and
BR MMI
Service Connector
Box
0166502N05 Motorola Sol-
utions
Used for measuring receiver
sensitivity
Basic Service Cable 3066565B01 Motorola Sol-
utions
Coaxial Directional
Coupler
3041-20 Narda Used for receive test signal
injection into duplex TX/RX
antenna port
Circulator, 260 MHz
band
Ferrocom
Circulator, 360 MHz–
405 MHz
9C30-41 Ferrocom
Circulator, 800 MHz–
900 MHz
9C78 Ferrocom
Load 375 BNM Narda
RF Attenuator, 10dB minimum 100 W Motorola Sol-
utions
Used to attenuate transmit
signals for testing
RF Adapter 33 QMA-N-50-
1/133 NE
Huber & Suh-
ner
“N” female to “QMA” male
RF Adapter 31 N-QMA- 1/1- -
NE
Huber & Suh-
ner
“N” female to “QMA” female
RF Adapter 33_716-N-50-1/- - -
_UE
Huber & Suh-
ner
N female to DIN 7-16 male
Rubidium Frequency
Standard
PRFS (or 2008) Ball/Efratom
(UCT)
Used as a frequency stand-
ard for receive test
6802800U74-AP
Chapter 6: Configuration and Testing