Users Manual Part 1

In-
dex
Cable
Part Num-
ber
From Unit / Connec-
tion Name
To Unit / Connection
Name
Notes
1 3066575B
01
Site Controller1/ CAN Power Supply Unit1/
CAN1
Red cable
2 3066544B
06
Power Supply Unit1/
CAN2
Duplexer 1 or Post Fil-
ter 1/ CAN1
Red cable
3 3066544B
09
Duplexer 1 or Post Fil-
ter1/ CAN2
Duplexer 2 or Post Fil-
ter 2/ CAN1
Red cable
4 3066544B
03
Duplexer 2 or Post Fil-
ter 2 / CAN2
ATCC 1/ CAN1 Red cable
5 3066544B
09
ATCC 1/ CAN2 ATCC 2/ CAN1 Red cable
6 3066544B
06
ATCC 2/ CAN2 Power Supply Unit2/
CAN1
Red cable
7 0966513A
01
Power Supply Unit2/
CAN2
CAN Bus termination without redundant
TCS
8 3066575B
01
Power Supply Unit2/
CAN2
Site Controller2/ CAN with redundant
Site Controller/
red cable
NOTICE: When MTCCs or HCs are used instead of ATCCs, the CAN Bus is connected directly
from Duplexer 2 or Post Filter 2/ CAN2 connector to Power Supply Unit2/ CAN1 connector.
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
234