Users Manual Part 1

In-
dex
Cable
Part
Number
From Unit To Unit Notes
bers on
page 204.
18 See Table
62: TX
ATCC
Phasing
Harness
Part Num-
bers on
page 217.
ATCC (3, 4) ATCC (1, 2)
in Prime Cab-
inet
TX path, Phasing Harness rout-
ed through conjunction hole at
side of the cabinet
19 3066543B
11
RX Splitter 1 /
Prime Cab
Duplexer 1/
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 1 or 2 ant.
20 3066543B
11
RX Splitter 2 /
Prime Cab
Duplexer 2 /
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 1 or 2 ant.
21 3066543B
11
RX Splitter 3 /
Prime Cab
Preselector /
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 2 ant.
NOTICE:
When MTCC is used instead of ATCC, connect the cables to corresponding inputs and outputs.
In the Prime Cabinet, detach the Post Filter cable in the prime cabinet from the T connector on
the Interconnect Harness in the prime. Connect the free end of the Phasing Harness from the
expansion cabinet to the T connector on the Interconnect Harness in the prime cabinet and
connect the Post Filter cable to the T connector in the Phasing Harness. This ensures that all
eight channels are connected to a single Post Filter.
RX cables from Filters in Prime Cabinet to RX Splitters in the Expansion Cabinet are routed
through holes on the back side of the top-lid.
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
223